Grill Care

Holland Grills will help you cook fantastic meals for many years. Following our cooking and grill care tips will help you get the most out of your Holland Grill. Click on one of the following categories to review the related tips.


Classic/ Classic II/ Premier/ Premier II Orifice Replacement Procedure

STEP 1 Turn valve to off position on LP tank.
STEP 2 Disconnect and remove regulator and hose from LP tank, by unscrewing
counter-clockwise the large black plastic nut.
STEP 3 Using "2" wrenches (5/8 & 3/4), loosen and remove hose from grill gas valve.
STEP 4 using a 5/8 wrench, loosen air shutter jam nut in front of burner Ventura.
STEP 5 Unscrew valve (counterclockwise) from burner.
STEP 6 Using a 3/8 wrench or socket, unscrew the orifice out of the end of the gas
valve that was screwed into the burner.
STEP 7 Replace with the correct size orifice.
STEP 8 Replace screen, air shutter and gas valve as it was originally. Tighten the
gas supply line with a 3/4 wrench. NOT BY HAND!
STEP 9 Re-adjust the air shutter for the correct setting. Flame should be blue with slight yellow tips.
STEP 10 Check for gas leaks with soapy water before re-lighting per instructions in
manual.

NOTE: When using natural gas, the LP regulator cannot be used.

Holland Authorized Orifice Sizes
PREMIER & PREMIER II LP #57 CLASSIC & CLASSIC II LP #55
PREMIER & PREMIER II NG #53 CLASSIC & CLASSIC II NG #48
SIDE BURNER SAME AS GRILLS

Note: Normal flame should be blue with slight yellow tips.